You are here: Home » Products » Residential Water Source Heat Pumps For Cooling And Heating
Residential Water Source Heat Pumps For Cooling And Heating
Click image to view full size image
Product: Views:503Residential Water Source Heat Pumps For Cooling And Heating 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-12-07 07:56
  Inquiry
Details

Residential water source heat pumps for cooling and heating 


This is residential water source heat pumps which can supply both cooling and heating functions. Use high quality one-way valve and solenoid valve for reliable cooling and heating, professional control system.

With unique design and long time testing, we can ensure the best performance.

With the high standard and professional workers, we ensure the high quality.


Product Info. 

Compressor

Copeland scroll or Panasonic scroll

Capacity

11KW, 17KW, 24KW

Refrigerant

R410A

Condenser

“ND” Shell & Coil heat exchanger

Evaporator

Shell & tube, tube in tube or plate type heat exchanger

AC contactor & Relay

Schneider

Electronic expansion valve

Japan Saginomiya or World No.1 Sanhua

Reversing valve

World No.1 Sanhua

Controller

LCD

Package

Wooden case or Carton

Fasteners

Stainless steel 304


Additional Info. 

Delivery time

25 days after order confirmed

Warranty time

24 months after shipment

Payment term

T/T or L/C at sight

Production capacity

300 units per month

Brand

MES or OEM


Parameters 

Cooler-RW series(Residential Water 

source cooling & heating heat pump

CL-RW-1609

CL11s-RW5 CL17s-RW5 CL11-RW5 CL17-RW5 CL24-RW5

Underground water 

open loop

Rated cooling

 capacity

KW 11 17 11 17 24

Rated input 

power 

for cooling

KW 2.15 3.34 2.11 3.2 4.72

Rated input 

current 

for cooling

A 9.55 14.84 3.98 6.04 8.91

Cooling performance 

coefficient (EER)

/ 5.12 5.09 5.22 5.32 5.09

Rated heating 

capacity

KW 9.5 16 9.5 16 22

Rated input 

power 

for heating

KW 2.59 4.38 2.59 4.31 6.09

Rated input 

current 

for heating

A 12.33 20.87 4.89 8.15 11.52

Heating 

performance 

coefficient (COP)

/ 3.67 3.65 3.67 3.71 3.61

Application 

side heat 

exchanger water 

flow

M3/h 1.89 2.92 1.89 2.92 4.13

Heat source 

side heat 

exchanger 

water flow

M3/h 1.03 1.59 1.03 1.59 2.25

Ground source 

closed loop

Rated cooling capacity KW 10 16 10 16 22

Rated input power 

for cooling

KW 1.96 3.17 1.95 3.13 4.38

Rated input current 

for cooling

A 8.7 14.11 3.68 5.91 8.28

Cooling performance 

coefficient (EER)

/ 5.11 5.04 5.13 5.12 5.02
Rated heating capacity KW 8 12 8 12 16

Rated input power 

for heating

KW 3.07 4.43 3.04 4.58 5.99

Rated input current 

for heating

A 13.27 19.17 5.66 8.52 11.15

Heating performance 

coefficient (COP)

/ 2.61 2.71 2.63 2.62 2.67

Application side heat 

exchanger water flow

M3/h 1.38 2.06 1.38 2.06 2.75

Heat source side heat 

exchanger water flow

M3/h 1.72 2.58 1.72 2.58 3.44
Power supply

1N 220V/50Hz (Special power

 supply for option)

3N 380V/50Hz

(Special power 

supply for option)

Compressor Type

Hermetic scroll type

Quantity PCS 1 1 1 1 1

Heat source side 

heat exchanger

Type

Shell & coil

heat exchanger

Connection size DN DN20 DN25 DN25 DN25 DN25

Application side 

heat exchanger

Type

Shell & coil

heat exchanger

Connection size DN DN20 DN25 DN25 DN25 DN25
Protections 1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
Refrigerant Type R410A
Quantity KG 2.6 3.3 2.6 3.3 4.2
Dimension mm 790x415x590
Wooden case package dimensions(L*W*H) mm 836x461x752
Net weight KG 68 95 65 95 135
Gross weight KG 78 105 75 105 145
Noise DB(A) ≤53 ≤55 ≤55 ≤55 ≤58
Note:
1. Underground water open loop type cooling standard condition: use side water input/output temperature 12℃/7℃; source side water input/output temperature 18/29℃.
Underground water open loop type heating standard condition: use side water input/output temperature 40℃/45℃; source side water input/output temperature 15℃/-a.
2. Ground source closed loop type cooling standard condition: use side water input/output temperature 12℃/7℃; source side water input/output temperature 25℃/30℃ Ground source closed loop type heating standard condition: use side water input/output temperature 40℃/45℃ ; source side water input/output temperature 5℃/-a.
3. "-a " means the water flow under cooling standard condition.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret.


MES, one of the professional manufacturers and suppliers of residential water source heat pumps for cooling and heating in China, has been developing and manufacturing heat pumps for over 10 years and become one of the famous such brands. In order to make customers 100% satisfied, we also offer installation service. Now, don't hesitate to buy high quality residential water source heat pumps for cooling and heating made in China at competitive price with our factory.

Inquiry